Back to Top

Hi, Guest!

  LOKASI :  Kota Tangerang Selatan

Bergabung Selama :

BAGIKAN :   

Bagikan :

PORTABLE GC ( Gas Chromatography)

Update Terakhir
:
17 / 09 / 2020
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
86 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail PORTABLE GC ( Gas Chromatography)

PID Analyzers offers a new lightweight portable GC for environmental, quality control, natural gas... applications. The base Model 312 comes with syringe injection, oven, power supplies & Pentium PC with Windows XP ( embedded) and PeakWorks chromatography software in a rugged plastic case. Specifications Detectors: Photoionization detector ( PID) , Flame ionization detector ( FID) , Thermal conductivity detector ( TCD) , Flame photometric detector ( FPD) , Far UV absorbance ( FUV) detector, Catalytic combustion detector ( CCD) Species measured: PID & FID: Organics ( VOCs by PID or FID) and inorganic species ( H2S, NH3, AsH3… ) that can be ionized by the PID lamp ( 9.5, 10.6 or 11.7 eV) TCD: Universal detector- fixed gases ( O2, N2, CO… ) , organic and inorganic compounds, very sensitive for H2, He, Xe FPD: Selective response for S or P compounds Far UV: Nearly universal response for organic and inorganic compounds CCD: Combustible compounds such as hydrocarbons Detection Limit: PID- 0.5 ppb benzene FID- 50 ppb benzene TCD- H2- 10 ppm; O2 150 ppm Linear Dynamic Range: PID- 108 FID- 2 x 106 TCD- 2 x 104 FPD- S- 103; P 105 Far UV- 106 CCD- 5 x 104 Sensor( s) : 1 or 2 detectors Precision: + / - 1-2% of reading Response time: : Depends on retention times Sample flow rate: > 0.5 LPM Injection: On-column syringe injection or automatic with 6 port gas valve ( optional) Span Drift: < 1% over 24 hours Zero Drift: NA- autozero on each run Power consumption: 1 GByte of RAM; data storage on 1 Gbyte USB memory stick Operating system Windows XP® embedded stored on 2.5 GByte smart card ( the PeakWorks program and all data are on the memory stick Peak Detection & System Operation: Controlled by our 32 bit PeakWorks software program with more than 20 years of development ADC Our 16 bit ADCs provide a resolution of 1 part in 64, 000 and our signal algorithm minimizes noise by signal averaging in the msec range; the ADC can acquire positive or negative signals Autoranging The 312 has 3 ranges with computer controlled autoranging- x1, x 10, x 100 Autozero Beginning of each run Programmable Voltage/ current output 0-1VDC Digital outputs USB connection Battery life 3-4 hours; can operate off cigarette lighter adapter Carrier gas 50 liters at 1500 PSI; typical capillary column 15-20 cc/ min; typical packed column 30-40 cc/ min Oven Size: Typical column diameter: 3.5” Temperatur range: Battery: 25-50 Degrees Celcius External power: 25-100 Degrees Celcius Programmable setpoints The low and high setpoints ( depends on the options) can be customer programmed for each point and/ or compound
gas analyzer
Tampilkan Lebih Banyak